| Model TIDAK.: | BPK-III | Rentang Pengukuran: | Pengukur Tekanan Menengah |
|---|---|---|---|
| Ketepatan: | 1 | Tipe Tampilan: | Digital |
| Catu daya: | AC85-260V | Tampilan LED: | -1999-9999 |
| Beralih Poin: | 2 poin | Catu Daya Sendiri: | 24VDC |
| Tegangan suplai: | 220VAC /24VDC(±10%) | Suhu lingkungan: | 0 ~ 50oC |
| KELEMBABAN RELATIF: | ≤85% Gas tidak korosif | Impedansi Masukan: | 100K |
| Output analog: | 4~20mA atau 0~20mA | Relay Kapasitas Kontak: | 250V/120V AC, 120V/48V AC, <48V AC |
| Relai Kehidupan: | >100000 kali | ||
| Menyoroti: | Pengukur tekanan AC85-260V,alat ukur tekanan input multi-sinyal,sensor tekanan silikon |
||
| Kode sinyal masukan | Sinyal Masuk | Jangkauan Tampilan | Resolusi | Keakuratan | Impedansi Masuk |
|---|---|---|---|---|---|
| 00 | T TC | 0 ~ 400oC | 1oC | 00,2% | 100 ribu |
| 01 | R TC | 0~1600oC | 1oC | 00,2% | 100 ribu |
| 02 | J TC | 0 ~ 1200oC | 1oC | 00,2% | 100 ribu |
| 03 | WRe3-WRe25 TC | 0 ~ 2300oC | 1oC | 00,2% | 100 ribu |
| 04 | B TC | 350 ~ 1800oC | 1oC | 00,2% | 100 ribu |
| 05 | S TC | 0~1600oC | 1oC | 00,2% | 100 ribu |
| 06 | K TC | 0~1300oC | 1oC | 00,2% | 100 ribu |
| 07 | E TC | 0 ~ 900oC | 1oC | 00,2% | 100 ribu |
| 08 | Pt100 RTD | -200 ~ 600,0oC | 0.1oC | 00,2% | 0.2mA |
| 09 | Cu50 RTD | -50,0 ~ 150,0oC | 0.1oC | 00,2% | 0.2mA |
| 10 | 0~375Ω tekanan jarak jauh | Dapat dikonfigurasi dari -1999 sampai 9999 | Sampel A/D 16 bit | 00,2% | 0.2mA |
| 11 | 0~75mV pembagi arus | 00,1% | 100 ribu | ||
| 12 | 0 ~ 30mV | 00,1% | 100 ribu | ||
| 13 | Sinyal standar 0 ~ 5V | 00,1% | 100 ribu | ||
| 14 | Sinyal standar 1 ~ 5V | 00,1% | 100 ribu | ||
| 15 | Sinyal standar 0 ~ 10V | 00,1% | 100 ribu | ||
| 16 | 0 ~ 10 mA sinyal standar | 00,1% | 20Ω | ||
| 17 | Sinyal standar 0 ~ 20 mA | 00,1% | 20Ω | ||
| 18 | Sinyal standar 4 ~ 20 mA | 00,1% | 20Ω |
| Menerjemahkan sinyal output | Output saat ini | Ruang Lingkup Pengiriman | Tegangan Terisolasi | Resolusi maksimum | Keakuratan | Kapasitas Beban | Tegangan sirkuit terbuka |
|---|---|---|---|---|---|---|---|
| 00 | 4 ~ 20 mA | Mengirim data dalam jangkauan ke sinyal arus standar | 1500V | 12 bit | 00,3% | ≤ 500Ω | 15V |
| 01 | 0 ~ 20mA |
| Tegangan | Max Current (Resistive Load) | Max Current (Induktif Load) | Kehidupan Relay |
|---|---|---|---|
| 250V/120V | 3A AC / 2A DC | 0.3A AC / 0.2A DC | >100.000 operasi |
| 120V/48V | 4A AC / 3A DC | 0.4A AC / 0.3A DC | |
| < 48V | 5A AC / 4A DC | 0.5A AC / 0.4A DC |
| Model | Dimensi garis besar | Dimensi output panel (mm) | Catatan |
|---|---|---|---|
| BPK-IIIS1 | 160×80×80 (Horizontal) | 152 + 0,8 × 76 + 0.7 | |
| BPK-IIIS2 | 96×48×112 (Horizontal) | 92 + 0,7 × 44 + 0.5 | |
| BPK-IIIN1 | 80×160×80 (vertikal) | 76 + 0,7 × 152 + 0.8 | |
| BPK-IIIN2 | 48×96×112 (vertikal) | 44 + 0,5 × 92 + 0.7 | |
| BPK-IIIF1 | 96×96×112 (Lembar) | 92 + 0,7 x 92 + 0.7 | |
| BPK-IIIF2 | 48×48×108 (Lembar) | 44 + 0,5 × 44 + 0.5 | Dengan lampu alarm J2 tanpa relay J2 |
| BPK-IIIF3 | 72×72×112 | 67 + 0,7 × 67 + 0.7 |